Sensor size (mm) | Image circle (mm) | Camera | Focal length 9.5 mm | Focal length 12 mm | Focal length 14 mm |
23.76 x 13.37 | 27.26 | ALEXA HD | V=70.3° H=103.0° D=110.6° | V=58.3° H=89.5° D=97.4° | V=51.1° H=80.6° D=88.5° |
22 x 16 | 27.20 | Normal 35 | V=80.3° H=98.6° D=110.5° | V=67.4° H=85.1° D=97.3° | V=59.5° H=76.3° D=88.3° |
24 x 18 | 30.00 | DIN Super 35 | V=87.0° H=103.5° D=115.7° | V=73.8° H=90.1° D=102.9° | V=65.5° H=81.2° D=94.0° |
24.9 x 18.7 | 31.14 | ANSI Super 35 | V=89.2° H=105.6° D=117.6° | V=75.9° H=92.2° D=105.0° | V=67.5° H=83.3° D=96.1° |
28.25 x 18.17 | 33.59 | ALEXA SXT & ALEXA Mini Open Gate | V=87.4° H=112.4° D=121.2° | V=74.2° H=99.3° D=109.0° | V=65.8° H=90.3° D=100.3° |
Entrance pupil position (7) | 310.4 mm 12.22“ | 309.9 mm 12.20“ | 309.4 mm 12.18“ |
Sensor size (mm) | Image circle (mm) | Camera | Focal length 16 mm | Focal length 18 mm |
23.76 x 13.37 | 27.26 | ALEXA HD | V=45.3° H=73.1° D=80.8° | V=40.8° H=66.8° D=74.2° |
22 x 16 | 27.20 | Normal 35 | V=53.1° H=68.9° D=80.6° | V=47.9° H=62.8° D=74.1° |
24 x 18 | 30.00 | DIN Super 35 | V=58.7° H=73.6° D=86.2° | V=53.1° H=67.3° D=79,5° |
24.9 x 18.7 | 31.14 | ANSI Super 35 | V=60.5° H=75.7° D=88.3° | V=54.9° H=69.3° D=81.6° |
28.25 x 18.17 | 33.59 | ALEXA SXT & ALEXA Mini Open Gate | V=59.0° H=82.6° D=92.5° | V=53.5° H=76.0° D=85.9° |
Entrance pupil position(7) | 308.7 mm 12.15“ | 308.0 mm 12.13“ |
Lens Mount(1) | PL LDS-1 |
Aperture | T2.9 - T22 |
Close Focus(2) | 0.55 m / 21.654“ |
Magnification Ratio(3) | 1:10.7 |
Length(4) | 335.5 mm / 13.209“ |
Length including flange focal distance(5) | 387.5 mm / 15.256“ |
Max. diameter excluding front and gear | 112 mm / 4.409“ |
Maximum Housing Diameter | |
Front Diameter(6) | 134 mm / 5.276“ or 156 mm / 6.142“ |
Weight | 4.8 kg / 10.6lb |
Item number meter | K2.47620.0 |
Item number feet | K2.0001686 |
(1) Lens Mount: Positive locking (PL) 54 mm stainless steel lens mount with Lens Data System (LDS) contacts.
(2) Close Focus: Close focus is measured from the film/sensor plane.
(3) Magnification ratio: Magnification Ratio is the relationship of the size of an object on the film/sensor plane (first number) to the size of that object in real life (second number) at the close focus setting; horizontal (H) and vertical (V).
(4) Length: Length is measured from the lens mount to the front of the lens housing.
(5) Length including flange focal distance: Length is measured from the image to the front of the lens housing.
(6) Front Diameter: Diameter of the lens/matte box interface.
(7) Entrance Pupil: The distance from the entrance pupil to the film/sensor plane at focus = infinity. Positive numbers indicated an entrance pupil in front, negative numbers indicated an entrance pupil behind the film/sensor plane. The entrance pupil (often mistakenly called "nodal point") is the center of perspective; moving the camera/lens system around the center of the entrance pupil prevents parallax errors. While largerly irrelevant for live action, this measurement is important for special effects work.